{"product_id":"vestas-v162-7-2-mw™-onshore-wind-turbine","title":"Vestas V162-7.2 MW™ Onshore Wind Turbine","description":"\u003cdiv class=\"hero aem-GridColumn aem-GridColumn--default--12\"\u003e\n\u003csection class=\"cmp-hero\"\u003e\n\u003cdiv class=\"grid-break grid-stack\"\u003e\n\u003cdiv class=\"cmp-hero__content--vh bs-container-fluid bs-container-max position-relative pe-none d-flex flex-row h-100 cmp-hero__content--bg-media\"\u003e\n\u003cdiv class=\"d-flex h-100 w-100\"\u003e\n\u003cdiv class=\"mt-auto pe-auto pb-5 flex-grow-1 text-white\"\u003e\n\u003cdiv class=\"cmp-hero__content--main  row gx-0 pb-1\"\u003e\n\u003cdiv class=\"col-12 col-md-6 ps-md-4\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cp\u003eThe V162-7.2 MW™ features flexible rating, designed to deliver optimized energy production even with greater temperature and climate variations. \u003c\/p\u003e\n\u003cdiv class=\"col-12 col-md-4\"\u003e\n\u003cdiv class=\"container-1 container responsivegrid mb-3\"\u003e\n\u003cdiv id=\"container-f8834a5f67\" class=\"cmp-container\"\u003e\n\u003cdiv class=\"text col-12\"\u003e\n\u003cdiv data-cmp-data-layer='{\"text-f0d87f6262\":{\"@type\":\"vestas\/components\/text\",\"repo:modifyDate\":\"2022-08-10T08:25:50Z\",\"xdm:text\":\"\u0026lt;p style=\\\"text-align: justify;\\\"\u0026gt;The\u0026amp;nbsp;V162-7.2 MW™ improves\u0026amp;nbsp;Annual\u0026amp;nbsp;Energy\u0026amp;nbsp;Production\u0026amp;nbsp;by up to 7%\u0026amp;nbsp;through enhancements in powertrain and power conversion systems combined with\u0026amp;nbsp;flexible ratings of 6.5 MW, 6.8 MW and 7.2 MW,\u0026amp;nbsp;while maintaining the maximum Sound Power Level at 104.6dB(A) operating at 6.8 MW.\u0026amp;nbsp;\u0026lt;br\u0026gt;\\r\\n\u0026lt;\/p\u0026gt;\\r\\n\u0026lt;p\u0026gt;\u0026amp;nbsp;\u0026lt;\/p\u0026gt;\\r\\n\"}}' id=\"text-f0d87f6262\" class=\"cmp-text\"\u003e\n\u003cp\u003eThe V162-7.2 MW™ improves Annual Energy Production by up to 7% through enhancements in powertrain and power conversion systems combined with flexible ratings of 6.5 MW, 6.8 MW and 7.2 MW, while maintaining the maximum Sound Power Level at 104.6dB(A) operating at 6.8 MW. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-12 col-md-4\"\u003e\n\u003cdiv class=\"container-2 container responsivegrid mb-3\"\u003e\n\u003cdiv id=\"container-d6935314d4\" class=\"cmp-container\"\u003e\n\u003cdiv class=\"text col-12\"\u003e\n\u003cdiv data-cmp-data-layer='{\"text-87d7a03bc7\":{\"@type\":\"vestas\/components\/text\",\"repo:modifyDate\":\"2022-04-05T06:29:25Z\",\"xdm:text\":\"\u0026lt;p style=\\\"text-align: justify;\\\"\u0026gt;Improved\u0026amp;nbsp;siteability\u0026amp;nbsp;in warm climates is enabled through the optional larger\u0026amp;nbsp;CoolerTop.\u0026amp;nbsp;Designed with full value chain in mind, the V162-7.2 MW™\u0026amp;nbsp;realises\u0026amp;nbsp;improved\u0026amp;nbsp;transportability of the nacelle unit, as well as the\u0026amp;nbsp;flexibility to service and upgrades over the turbine’s operational lifetime.\u0026lt;\/p\u0026gt;\\r\\n\"}}' id=\"text-87d7a03bc7\" class=\"cmp-text\"\u003e\n\u003cp\u003eImproved siteability in warm climates is enabled through the optional larger CoolerTop. Designed with the full value chain in mind, the V162-7.2 MW™ realizes improved transportability of the nacelle unit, as well as the flexibility to service and upgrades over the turbine’s operational lifetime.\u003c\/p\u003e\n\u003cp\u003eThe V162-7.2 MW™ is designed for medium to high wind sites combined with extreme wind speeds of up to 41.5 m\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-cmp-data-layer='{\"text-0aae34a4b9\":{\"@type\":\"vestas\/components\/text\",\"repo:modifyDate\":\"2025-12-11T09:31:21Z\",\"xdm:text\":\"\u0026lt;p\u0026gt;The V136-4.2 MW™ is designed for low to medium wind sites and offers a competitive sound power level.\u0026lt;\/p\u0026gt;\\r\\n\"}}'\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAvailable options\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6.5 MW Operational Mode\u003c\/li\u003e\n\u003cli\u003e6.8 MW Operational Mode\u003c\/li\u003e\n\u003cli\u003e7.2 MW Operational Mode\u003c\/li\u003e\n\u003cli\u003eOil Debris Monitoring System\u003c\/li\u003e\n\u003cli\u003eHigh Temperature Cooler Top\u003c\/li\u003e\n\u003cli\u003eService Personnel Lift\u003c\/li\u003e\n\u003cli\u003eLow Temperature Operation to -30°C\u003c\/li\u003e\n\u003cli\u003eVestas Ice Detection™\u003cmeta charset=\"UTF-8\"\u003e\n\u003c\/li\u003e\n\u003cli\u003eVestas Anti-Icing System™\u003c\/li\u003e\n\u003cli\u003eVestas Shadow Flicker Control System\u003c\/li\u003e\n\u003cli\u003eAviation Lights\u003c\/li\u003e\n\u003cli\u003eAviation Markings on the Blades\u003c\/li\u003e\n\u003cli\u003eFire Suppression System\u003c\/li\u003e\n\u003cli\u003eVestas Bat Protection System\u003c\/li\u003e\n\u003cli\u003eLightning Detection System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"d-flex flex-lg-row flex-column\"\u003e\n\u003cdiv\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTechnical specifications\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003ePOWER REGULATION OPERATIONAL DATA\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003ePitch regulated with variable speed\u003c\/div\u003e\n\u003cdiv\u003eRated power:  \u003cmeta charset=\"UTF-8\"\u003e \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e7,200kW\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eCut-in wind speed:  3m\/s\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eCut-out wind speed:  25m\/s\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eWind class: \u003cmeta charset=\"UTF-8\"\u003e \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003eIEC S\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eStandard operating temperature range:  from -20°C** to +45°C \u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eSOUND POWER\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"d-flex col-7 col-md-8 px-0\"\u003e\n\u003cdiv\u003eMaximum:  \u003cmeta charset=\"UTF-8\"\u003e \u003cmeta charset=\"UTF-8\"\u003e105.5dB(A)**Sound Optimised Modes available dependent on site and country\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eROTOR\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eRotor diameter:  162m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eSwept area:  \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e20,612m2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eAerodynamic brake:  full blade feathering with 3 pitch cylinders\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eFrequency:  50\/60 Hz\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eConverter:  full scale\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eGEARBOX\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eType:  two planetary stages\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eTOWER\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eHub heights:  \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e119 m (IEC S\/DIBt S), 138 m (IEC S), 166 m (IEC S) and 169 m (DIBt S)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eSUSTAINABILITY METRICS\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eCarbon Footprint:  7.1g CO2e\/kWh\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eReturn on energy break-even:  7.4 months\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eLifetime return on energy:  32 times\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"cmp-datasheet__row row justify-content-between flex-wrap flex-md-nowrap m-0\"\u003e\n\u003cdiv class=\"d-flex col-7 col-md-8 px-0\"\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"d-flex col-7 col-md-8 px-0\"\u003e\n\u003cdiv\u003eRecyclability rate:  87%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003eConfiguration: 166m hub height, Vavg=7.4m\/s, k=2.48. Depending on site-specific conditions. Metrics are based on an internal streamlined assessment. An externally reviewed Life Cycle Assessment will be made available on vestas.com once finalized.\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0713\/5730\/1030\/files\/Screenshot2026-10-07at2.01.14PM.png?v=1791367283\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"vestas.com","offers":[{"title":"Default Title","offer_id":54038316450086,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0713\/5730\/1030\/files\/162-7.2HERO.jpg?v=1791367220","url":"https:\/\/evergreenbotany.com\/cs\/products\/vestas-v162-7-2-mw%e2%84%a2-onshore-wind-turbine","provider":"EVERGREEN","version":"1.0","type":"link"}